{"id":16314,"date":"2021-06-01T06:53:46","date_gmt":"2021-06-01T10:53:46","guid":{"rendered":"https:\/\/origin-www.parsons.com\/?p=16314"},"modified":"2022-10-04T14:45:38","modified_gmt":"2022-10-04T18:45:38","slug":"full-scale-fentons-chemistry-oxidation-using-native-iron-for-the-destruction-of-14-dioxane-in-recovered-groundwater","status":"publish","type":"post","link":"https:\/\/www.parsons.com\/2021\/06\/full-scale-fentons-chemistry-oxidation-using-native-iron-for-the-destruction-of-14-dioxane-in-recovered-groundwater\/","title":{"rendered":"Full-Scale Fenton’s Chemistry Oxidation Using Native Iron For The Destruction Of 1,4-Dioxane In Recovered Groundwater"},"content":{"rendered":"\n
\"Technical<\/figure>\n\n\n\n

A Technical Webinar Series <\/h2>\n\n\n\n

Presentation Description<\/h4>\n\n\n\n

We operate and maintain a groundwater treatment facility for an Industrial client in the northeastern United States. The treatment facility was designed to remove per- and polyfluoroalkyl substances (PFAS), volatile organic compounds (VOCs), and nuisance metals from extracted groundwater. A recent change in the groundwater discharge standard for 1,4-Dioxane required upgrades to the treatment facility\u2019s process treatment to improve 1,4-Dioxane removal efficiency. We are currently involved in the design of the full-scale facility upgrades to enhance 1,4-Dioxane removal while achieving treatment goals for PFAS, VOCs, and other constituents.<\/p>\n\n\n\n

Approach\/Activities<\/h4>\n\n\n\n

A tiered approach was used for technology selection for the treatment facility. Based on preliminary technology screening, two Advanced Oxidation Processes (AOPs) (ultraviolet [UV]\/peroxide and Fenton\u2019s chemistry) and one adsorptive (Ambersorb\u2122) treatment process were selected for bench or pilot testing. A cost evaluation was performed in parallel for the piloted technologies.<\/p>\n\n\n\n

Results\/Lessons Learned<\/h4>\n\n\n\n

Based on the demonstrated treatment efficacy and the life-cycle cost evaluation, 1,4-Dioxane oxidation using Fenton\u2019s chemistry was selected as the preferred treatment technology for the facility. Fenton\u2019s chemistry oxidation demonstrated complete destruction of 1,4-Dioxane in bench and pilot-scale studies at the lowest cost for all options evaluated. In this instance, the application of Fenton\u2019s chemistry for 1,4-Dioxane treatment utilizes an innovative and sustainable approach that uses the groundwater\u2019s native high iron content, eliminating the need for the addition of allochthonous sources of ferrous iron. The site\u2019s existing infrastructure (solids handling) can also be reutilized, resulting in a treatment option with the lowest capital and operations and maintenance (O&M) costs for implementation.<\/p>\n\n\n\n

<\/span>
About The Presenter<\/h5>

Ajish Nambiar has more than 15 years of experience working on groundwater treatment, industrial, municipal wastewater treatment, and water reuse projects. Ajish is a principal engineer with Parsons providing project delivery of capital projects from planning and concept development through engineering and detailed design, construction, commissioning, and startup.<\/p><\/div><\/figure>\n\n\n\n